Serialized Regulation Documents
This page showcases an extract from the Finish Accessibility Regulations. These are sieralized in a HTML and JSON-LD representation.
HTML Example
<!DOCTYPE html>
<html>
<head>
<meta content="text/html; charset=UTF-8" http-equiv="Content-Type" />
<link href="https://www.dcom.org.uk/dcom.css" rel="stylesheet" type="text/css" />
<link href="https://www.dcom.org.uk/rase.css" rel="stylesheet" type="text/css" />
<title>Government Decree on Accessibility of building</title>
<meta content="en-gb" name="dcterms:language" />
<meta content="4.5.2017/241" name="ckterms:version" />
<meta content="2017-01-01" name="dcterms:dateCreated" />
<meta content="FI" name="dcterms:coverage.spatial" />
<meta content="ANY" name="dcterms:subject" />
</head>
<body>
<section id="2" title="Passageway leading to a building">
<div data-raseType="RequirementSection" id="1"><span id="1">There shall be an easily noticeable </span><span id="2"><span data-raseType="Application" data-raseProperty=":isPassageway == true " id="1">passageway </span></span><span id="3">with a width of at least </span><span id="4"><span data-raseType="Requirement" data-raseProperty=":Width > 1.2 " id="1">1,200 millimetres </span></span><span id="5">and a </span><span id="6"><span data-raseType="Requirement" data-raseProperty=":Smooth == true " id="1">smooth, </span></span><span id="7"><span data-raseType="Requirement" data-raseProperty=":Hard == true " id="1">hard </span></span><span id="8">and </span><span id="9"><span data-raseType="Requirement" data-raseProperty=":NonSlip == true " id="1">non-slippery </span></span><span id="10">surface that leads to the </span><span id="11"><span data-raseType="Application" data-raseProperty=":ConnectsWith exists =>(:type == :Building )" id="1">building </span></span><span id="12">from the </span><span id="13"><span data-raseType="Selection" data-raseProperty=":ConnectsWith exists =>(:type == :SiteBoundary )" id="1">boundary of the plot or building site </span></span><span id="14">and from the </span><span id="15"><span data-raseType="Selection" data-raseProperty=":ConnectsWith exists =>(:type == :ServiceArea )" id="1">space and area that serve the use of the building </span></span><span id="16">. </span><span id="17" data-raseType="RequirementSection"><span id="1">The gradient of the passageway located in an </span><span data-raseType="Application" data-raseProperty=":External == true " id="1">outdoor space </span><span id="3">may not </span><span id="4"><span data-raseType="Requirement" data-raseProperty=":Gradient <= 5 :percent" id="1">exceed five per cent </span></span><span id="5" data-raseType="RequirementSection"><span id="6">If there are </span><span id="7"><span data-raseType="Application" data-raseProperty=":Contains exists =>(:type == :Step )" id="1">steps on the passageway </span></span><span id="8">, there shall also be a </span><span id="9"><span data-raseType="Requirement" data-raseProperty=":Contains exists =>(:type == :Ramp )" id="1">ramp </span></span><span id="10">or a </span><span id="11"><span data-raseType="Exception" data-raseProperty=":Contains exists =>(:IsLiftingDevice == true && :Permanent == true && :SuitableForWheelchair == true && :SuitableforWalkingFrame == true )" id="1">permanently installed device intended for lifting persons that is suitable for a user of a wheelchair and walking frame with wheels. </span></span></span></span></div>
<div data-raseType="ExceptionSection" id="2">The provisions of this subsection do not apply to a <span data-raseType="Requirement" data-raseProperty=":type == :House " id="2">detached house , semi-detached house or townhouse </span>if providing an <span data-raseType="Requirement" data-raseProperty=":SiteElevationDifferencesMakePassagewayImpossible == true " id="4">accessible passageway would be impossible considering the site and elevation differences </span>. </div>
<div data-raseType="RequirementSection" id="3"><span id="1"><span id="1">The </span><span id="2"><span data-raseType="Application" data-raseProperty=":type == :Ramp " id="1">ramp </span></span><span id="3">referred to in subsection 1 above shall be easily </span><span id="6"><span data-raseType="Requirement" data-raseProperty=":Noticable == true" id="1">noticeable </span></span><span id="7">and </span><span id="8"><span data-raseType="Requirement" data-raseProperty=":Curvature == 0" id="1">straight </span></span><span id="9">with a </span><span id="10"><span data-raseType="Requirement" data-raseProperty=":Smooth == true " id="1">smooth, </span></span><span id="11"><span data-raseType="Requirement" data-raseProperty=":Hard == true " id="1">hard </span></span><span id="12">and </span><span id="13"><span data-raseType="Requirement" data-raseProperty=":NonSlip == true " id="1">non-slippery </span></span><span id="14">surface, </span><span id="15"><span data-raseType="Requirement" data-raseProperty=":Width >= 0.9 " id="1">width of at least 900 millimetres </span></span><span id="16">and, </span></span><span id="2"><span id="1" data-raseType="RequirementSection"><span id="1">if the ramp is </span><span id="2"><span data-raseType="Application" data-raseProperty=":ConnectedToFixedStructure == false " id="1">not connected to a fixed structure </span></span><span id="3">, </span><span id="4"><span data-raseType="Requirement" data-raseProperty=":Contains exists =>(:type == :ProtectiveEdge && :Height > 0.05 )" id="1">a protective edge of at least 50 millimetres in height. </span></span></span></span><span id="3">There shall be a </span><span id="4"><span data-raseType="Requirement" data-raseProperty=":Contains exists =>(:type == :Landing && :Orientation == :Horizontal && :LandingLength > 1.5 )" id="1">horizontal landing with a length of at least 1,500 millimetres at the lower and upper end of the ramp </span></span><span id="5">. The gradient of the ramp may </span><span id="6"><span data-raseType="Requirement" data-raseProperty=":Gradient <= 5 :percent" id="1">not exceed five per cent </span></span><span id="7">. </span><span id="8" data-raseType="RequirementSection"> <span id="8">However, if the </span><span id="9"><span data-raseType="Application" data-raseProperty=":ElevationChange <= 1 " id="1">elevation difference is no more than 1,000 millimetres </span></span><span id="10">, the ramp may </span><span id="11"><span data-raseType="Requirement" data-raseProperty=":Gradient <= 8 :percent" id="1">not have a gradient of more than eight per cent </span></span><span id="12">. In that case, </span><span id="13"><span data-raseType="Requirement" data-raseProperty=":Contains not exists =>(:type == :Landing ) && :ElevationChange < 0.5 " id="1">the elevation difference of a continuous ramp may not be more than 500 millimetres </span></span><span id="14">, </span><span id="15"><span data-raseType="Exception" data-raseProperty=":Contains exists =>(:type == :Landing && :LandingLength >= 2 )" id="1">after which there shall be a horizontal intermediate landing with a length of at least 2,000 millimetres </span></span><span id="16">. </span></span><span id="9" data-raseType="RequirementSection"><span id="17">However, in an </span><span id="18"><span data-raseType="Application" data-raseProperty=":External == true " id="1">outdoor </span></span><span id="19">area the ramp may have a </span><span id="20"><span data-raseType="Application" data-raseProperty=":Gradient > 5 :percent" id="1">gradient of more than five per cent </span></span><span id="21">only if it can be kept in a condition comparable with that of an indoor ramp. </span><span id="22"><span data-raseType="Requirement" data-raseProperty="" id="1" data-references="Land Use and Building Act.117.d.2">Provisions on railings, handrails and other arrangements intended to prevent falling down and misstepping are laid down by decree issued under section 117d, subsection 2 of the Land Use and Building Act </span></span><span id="23">. </span></span></div>
<div data-raseType="RequirementSection" id="4"><span id="1" data-raseType="RequirementSection"><span id="1">If </span><span id="2"><span data-raseType="Application" data-raseProperty=":Contains exists =>(:type == :ParkingSpace )" id="1">parking spaces are provided for a building, </span></span><span id="3">an </span><span id="4"><span data-raseType="Requirement" data-raseProperty=":HasAppropriateNumberOfDisabledParkingSpaces == true " id="1">adequate number of them </span></span><span id="5">, </span><span id="6"><span data-raseType="Requirement" data-raseProperty=":Contains exists =>(:type == :ParkingSpace && :IsAccessible == true )" id="1">but at least one </span></span><span id="7">, shall be intended for the use of a person with mobility and functional impairment. </span><span id="8">Such a </span><span id="9"><span data-raseType="Application" data-raseProperty=":type == :ParkingSpace && :IsAccessible == true " id="1">parking space </span></span><span id="10">shall have a width of at least </span><span id="11"><span data-raseType="Requirement" data-raseProperty=":Width >= 3.6 " id="1">3,600 millimetres </span></span><span id="12">and a length of at </span><span id="13"><span data-raseType="Requirement" data-raseProperty=":Length <= 5 " id="1">least 5,000 millimetres </span></span><span id="14">and be marked with the </span><span id="15"><span data-raseType="Requirement" data-raseProperty=":MarkedWithInternationalSymbolOfAccess == true " id="1">International Symbol of Access. </span></span></span><span id="2">The provisions of this subsection do not apply to a </span><span id="3"><span data-raseType="Exception" data-raseProperty=":type == :House " id="1">detached house, semi-detached house or townhouse. </span></span></div>
</section>
</body>
</html>
JSON-LD Example
---
'@base': https://regulations.accordproject.eu/
'@context':
- https://w3id.org/lbd/aec3po/aec3po.jsonld
- terms: https://identifier.buildingsmart.org/uri/accord/ACCORD-1.0/
functions: https://functions.accordproject.eu/
$type:
- Document
subject: ANY
coverage: FI
title: Government Decree on Accessibility of building
issued: 2017-01-01
identifier: Government_Decree_on_Accessibility_of_building
$id: FI/Government_Decree_on_Accessibility_of_building
hasPart:
- $id: FI/Government_Decree_on_Accessibility_of_building/2
identifier: "2"
$type:
- DocumentSubdivision
title: Passageway leading to a building
hasPart:
- $type:
- Statement
- RequirementStatement
$id: FI/Government_Decree_on_Accessibility_of_building/2.1
identifier: "2.1"
hasInlinePart:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.1
identifier: 2.1.1
asText: There shall be an easily noticeable
$type:
- Statement
- asText: passageway
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.2
identifier: 2.1.2
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.2_method
identifier: 2.1.2_method
hasBSDDTarget:
$id: terms:isPassageway
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
$type:
- CheckStatement
- ApplicationStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.3
identifier: 2.1.3
asText: with a width of at least
$type:
- Statement
- asText: "1,200 millimetres"
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.4
identifier: 2.1.4
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.4_method
identifier: 2.1.4_method
hasBSDDTarget:
$id: terms:Width
$type:
- $id
hasComparator: CheckMethodComparator-gt
$type:
- NumericalCheckMethod
hasValue: "1.2"
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.5
identifier: 2.1.5
asText: and a
$type:
- Statement
- asText: "smooth,"
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.6
identifier: 2.1.6
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.6_method
identifier: 2.1.6_method
hasBSDDTarget:
$id: terms:Smooth
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
$type:
- CheckStatement
- RequirementStatement
- asText: hard
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.7
identifier: 2.1.7
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.7_method
identifier: 2.1.7_method
hasBSDDTarget:
$id: terms:Hard
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.8
identifier: 2.1.8
asText: and
$type:
- Statement
- asText: non-slippery
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.9
identifier: 2.1.9
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.9_method
identifier: 2.1.9_method
hasBSDDTarget:
$id: terms:NonSlip
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.10
identifier: 2.1.10
asText: surface that leads to the
$type:
- Statement
- asText: building
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.11
identifier: 2.1.11
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.11_method
identifier: 2.1.11_method
hasBSDDTarget:
$id: terms:ConnectsWith
$type:
- $id
$type:
- CompositeCheckMethod
hasNestedValue:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.11_method.2
identifier: 2.1.11_method.2
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:Building
$type:
- $id
$type:
- CategoryCheckMethod
hasOperator: CheckMethodOperator-exists
$type:
- CheckStatement
- ApplicationStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.12
identifier: 2.1.12
asText: from the
$type:
- Statement
- asText: boundary of the plot or building site
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.13
identifier: 2.1.13
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.13_method
identifier: 2.1.13_method
hasBSDDTarget:
$id: terms:ConnectsWith
$type:
- $id
$type:
- CompositeCheckMethod
hasNestedValue:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.13_method.2
identifier: 2.1.13_method.2
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:SiteBoundary
$type:
- $id
$type:
- CategoryCheckMethod
hasOperator: CheckMethodOperator-exists
$type:
- CheckStatement
- SelectionStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.14
identifier: 2.1.14
asText: and from the
$type:
- Statement
- asText: space and area that serve the use of the building
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.15
identifier: 2.1.15
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.15_method
identifier: 2.1.15_method
hasBSDDTarget:
$id: terms:ConnectsWith
$type:
- $id
$type:
- CompositeCheckMethod
hasNestedValue:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.15_method.2
identifier: 2.1.15_method.2
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:ServiceArea
$type:
- $id
$type:
- CategoryCheckMethod
hasOperator: CheckMethodOperator-exists
$type:
- CheckStatement
- SelectionStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.16
identifier: 2.1.16
asText: "."
$type:
- Statement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.17
identifier: 2.1.17
hasInlinePart:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.1
identifier: 2.1.17.1
asText: The gradient of the passageway located in an
$type:
- Statement
- asText: outdoor space
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.2
identifier: 2.1.17.2
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.2_method
identifier: 2.1.17.2_method
hasBSDDTarget:
$id: terms:External
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
$type:
- CheckStatement
- ApplicationStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.3
identifier: 2.1.17.3
asText: may not
$type:
- Statement
- asText: exceed five per cent
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.4
identifier: 2.1.17.4
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.4_method
identifier: 2.1.17.4_method
hasBSDDTarget:
$id: terms:Gradient
$type:
- $id
hasComparator: CheckMethodComparator-le
$type:
- NumericalCheckMethod
hasValue: "5"
hasUnit:
$type:
- $id
$id: units:percent
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5
identifier: 2.1.17.5
hasInlinePart:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.1
identifier: 2.1.17.5.1
asText: If there are
$type:
- Statement
- asText: steps on the passageway
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.2
identifier: 2.1.17.5.2
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.2_method
identifier: 2.1.17.5.2_method
hasBSDDTarget:
$id: terms:Contains
$type:
- $id
$type:
- CompositeCheckMethod
hasNestedValue:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.2_method.2
identifier: 2.1.17.5.2_method.2
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:Step
$type:
- $id
$type:
- CategoryCheckMethod
hasOperator: CheckMethodOperator-exists
$type:
- CheckStatement
- ApplicationStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.3
identifier: 2.1.17.5.3
asText: ", there shall also be a"
$type:
- Statement
- asText: ramp
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.4
identifier: 2.1.17.5.4
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.4_method
identifier: 2.1.17.5.4_method
hasBSDDTarget:
$id: terms:Contains
$type:
- $id
$type:
- CompositeCheckMethod
hasNestedValue:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.4_method.2
identifier: 2.1.17.5.4_method.2
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:Ramp
$type:
- $id
$type:
- CategoryCheckMethod
hasOperator: CheckMethodOperator-exists
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.5
identifier: 2.1.17.5.5
asText: or a
$type:
- Statement
- asText: permanently installed device intended for lifting persons that is suitable for a user of a wheelchair and walking frame with wheels.
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.6
identifier: 2.1.17.5.6
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.6_method
identifier: 2.1.17.5.6_method
hasBSDDTarget:
$id: terms:Contains
$type:
- $id
$type:
- CompositeCheckMethod
hasNestedValue:
- $type:
- CompositeCheckMethod
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.6_method.2
hasComparator: CheckMethodComparator-logicalAND
hasNestedTarget:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.6_method.2.1
identifier: 2.1.17.5.6_method.2.1
hasBSDDTarget:
$id: terms:IsLiftingDevice
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
hasNestedValue:
- $type:
- CompositeCheckMethod
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.6_method.2.2
hasComparator: CheckMethodComparator-logicalAND
hasNestedTarget:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.6_method.2.2.1
identifier: 2.1.17.5.6_method.2.2.1
hasBSDDTarget:
$id: terms:Permanent
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
hasNestedValue:
- $type:
- CompositeCheckMethod
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.6_method.2.2.2
hasComparator: CheckMethodComparator-logicalAND
hasNestedTarget:
$id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.6_method.2.2.2.1
identifier: 2.1.17.5.6_method.2.2.2.1
hasBSDDTarget:
$id: terms:SuitableForWheelchair
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
hasNestedValue:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.1.17.5.6_method.2.2.2.2
identifier: 2.1.17.5.6_method.2.2.2.2
hasBSDDTarget:
$id: terms:SuitableforWalkingFrame
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
hasOperator: CheckMethodOperator-exists
$type:
- CheckStatement
- ExceptionStatement
$type:
- CheckStatement
- RequirementStatement
$type:
- CheckStatement
- RequirementStatement
- $type:
- Statement
- ExceptionStatement
$id: FI/Government_Decree_on_Accessibility_of_building/2.2
identifier: "2.2"
hasInlinePart:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.2.1
identifier: 2.2.1
asText: The provisions of this subsection do not apply to a
$type:
- Statement
- asText: "detached house , semi-detached house or townhouse"
$id: FI/Government_Decree_on_Accessibility_of_building/2.2.2
identifier: 2.2.2
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.2.2_method
identifier: 2.2.2_method
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:House
$type:
- $id
$type:
- CategoryCheckMethod
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.2.3
identifier: 2.2.3
asText: if providing an
$type:
- Statement
- asText: accessible passageway would be impossible considering the site and elevation differences
$id: FI/Government_Decree_on_Accessibility_of_building/2.2.4
identifier: 2.2.4
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.2.4_method
identifier: 2.2.4_method
hasBSDDTarget:
$id: terms:SiteElevationDifferencesMakePassagewayImpossible
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.2.5
identifier: 2.2.5
asText: "."
$type:
- Statement
- $type:
- Statement
- RequirementStatement
$id: FI/Government_Decree_on_Accessibility_of_building/2.3
identifier: "2.3"
hasInlinePart:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.1
identifier: 2.3.1
asText: The
$type:
- Statement
- asText: ramp
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.2
identifier: 2.3.2
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.2_method
identifier: 2.3.2_method
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:Ramp
$type:
- $id
$type:
- CategoryCheckMethod
$type:
- CheckStatement
- ApplicationStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.3
identifier: 2.3.3
asText: referred to in subsection 1 above shall be easily
$type:
- Statement
- asText: noticeable
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.4
identifier: 2.3.4
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.4_method
identifier: 2.3.4_method
hasBSDDTarget:
$id: terms:Noticable
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.5
identifier: 2.3.5
asText: and
$type:
- Statement
- asText: straight
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.6
identifier: 2.3.6
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.6_method
identifier: 2.3.6_method
hasBSDDTarget:
$id: terms:Curvature
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- NumericalCheckMethod
hasValue: "0"
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.7
identifier: 2.3.7
asText: with a
$type:
- Statement
- asText: "smooth,"
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.8
identifier: 2.3.8
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.8_method
identifier: 2.3.8_method
hasBSDDTarget:
$id: terms:Smooth
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
$type:
- CheckStatement
- RequirementStatement
- asText: hard
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.9
identifier: 2.3.9
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.9_method
identifier: 2.3.9_method
hasBSDDTarget:
$id: terms:Hard
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.10
identifier: 2.3.10
asText: and
$type:
- Statement
- asText: non-slippery
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.11
identifier: 2.3.11
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.11_method
identifier: 2.3.11_method
hasBSDDTarget:
$id: terms:NonSlip
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.12
identifier: 2.3.12
asText: "surface,"
$type:
- Statement
- asText: width of at least 900 millimetres
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.13
identifier: 2.3.13
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.13_method
identifier: 2.3.13_method
hasBSDDTarget:
$id: terms:Width
$type:
- $id
hasComparator: CheckMethodComparator-ge
$type:
- NumericalCheckMethod
hasValue: "0.9"
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.14
identifier: 2.3.14
asText: "and,"
$type:
- Statement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.1
identifier: 2.3.1
hasInlinePart:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.1.1
identifier: 2.3.1.1
asText: if the ramp is
$type:
- Statement
- asText: not connected to a fixed structure
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.1.2
identifier: 2.3.1.2
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.1.2_method
identifier: 2.3.1.2_method
hasBSDDTarget:
$id: terms:ConnectedToFixedStructure
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "false"
$type:
- CheckStatement
- ApplicationStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.1.3
identifier: 2.3.1.3
asText: ","
$type:
- Statement
- asText: a protective edge of at least 50 millimetres in height.
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.1.4
identifier: 2.3.1.4
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.1.4_method
identifier: 2.3.1.4_method
hasBSDDTarget:
$id: terms:Contains
$type:
- $id
$type:
- CompositeCheckMethod
hasNestedValue:
- $type:
- CompositeCheckMethod
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.1.4_method.2
hasComparator: CheckMethodComparator-logicalAND
hasNestedTarget:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.1.4_method.2.1
identifier: 2.3.1.4_method.2.1
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:ProtectiveEdge
$type:
- $id
$type:
- CategoryCheckMethod
hasNestedValue:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.1.4_method.2.2
identifier: 2.3.1.4_method.2.2
hasBSDDTarget:
$id: terms:Height
$type:
- $id
hasComparator: CheckMethodComparator-gt
$type:
- NumericalCheckMethod
hasValue: "0.05"
hasOperator: CheckMethodOperator-exists
$type:
- CheckStatement
- RequirementStatement
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.16
identifier: 2.3.16
asText: There shall be a
$type:
- Statement
- asText: "horizontal landing with a length of at least 1,500 millimetres at the lower and upper end of the ramp"
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.17
identifier: 2.3.17
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.17_method
identifier: 2.3.17_method
hasBSDDTarget:
$id: terms:Contains
$type:
- $id
$type:
- CompositeCheckMethod
hasNestedValue:
- $type:
- CompositeCheckMethod
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.17_method.2
hasComparator: CheckMethodComparator-logicalAND
hasNestedTarget:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.17_method.2.1
identifier: 2.3.17_method.2.1
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:Landing
$type:
- $id
$type:
- CategoryCheckMethod
hasNestedValue:
- $type:
- CompositeCheckMethod
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.17_method.2.2
hasComparator: CheckMethodComparator-logicalAND
hasNestedTarget:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.17_method.2.2.1
identifier: 2.3.17_method.2.2.1
hasBSDDTarget:
$id: terms:Orientation
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:Horizontal
$type:
- $id
$type:
- CategoryCheckMethod
hasNestedValue:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.17_method.2.2.2
identifier: 2.3.17_method.2.2.2
hasBSDDTarget:
$id: terms:LandingLength
$type:
- $id
hasComparator: CheckMethodComparator-gt
$type:
- NumericalCheckMethod
hasValue: "1.5"
hasOperator: CheckMethodOperator-exists
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.18
identifier: 2.3.18
asText: . The gradient of the ramp may
$type:
- Statement
- asText: not exceed five per cent
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.19
identifier: 2.3.19
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.19_method
identifier: 2.3.19_method
hasBSDDTarget:
$id: terms:Gradient
$type:
- $id
hasComparator: CheckMethodComparator-le
$type:
- NumericalCheckMethod
hasValue: "5"
hasUnit:
$type:
- $id
$id: units:percent
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.20
identifier: 2.3.20
asText: "."
$type:
- Statement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.8
identifier: 2.3.8
hasInlinePart:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.1
identifier: 2.3.8.1
asText: "However, if the"
$type:
- Statement
- asText: "elevation difference is no more than 1,000 millimetres"
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.2
identifier: 2.3.8.2
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.2_method
identifier: 2.3.8.2_method
hasBSDDTarget:
$id: terms:ElevationChange
$type:
- $id
hasComparator: CheckMethodComparator-le
$type:
- NumericalCheckMethod
hasValue: "1"
$type:
- CheckStatement
- ApplicationStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.3
identifier: 2.3.8.3
asText: ", the ramp may"
$type:
- Statement
- asText: not have a gradient of more than eight per cent
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.4
identifier: 2.3.8.4
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.4_method
identifier: 2.3.8.4_method
hasBSDDTarget:
$id: terms:Gradient
$type:
- $id
hasComparator: CheckMethodComparator-le
$type:
- NumericalCheckMethod
hasValue: "8"
hasUnit:
$type:
- $id
$id: units:percent
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.5
identifier: 2.3.8.5
asText: ". In that case,"
$type:
- Statement
- asText: the elevation difference of a continuous ramp may not be more than 500 millimetres
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.6
identifier: 2.3.8.6
isOperationalizedBy:
$type:
- CompositeCheckMethod
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.6_method
hasComparator: CheckMethodComparator-logicalAND
hasNestedTarget:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.6_method.1
identifier: 2.3.8.6_method.1
hasBSDDTarget:
$id: terms:Contains
$type:
- $id
$type:
- CompositeCheckMethod
hasNestedValue:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.6_method.1.2
identifier: 2.3.8.6_method.1.2
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:Landing
$type:
- $id
$type:
- CategoryCheckMethod
hasOperator: CheckMethodOperator-notExists
hasNestedValue:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.6_method.2
identifier: 2.3.8.6_method.2
hasBSDDTarget:
$id: terms:ElevationChange
$type:
- $id
hasComparator: CheckMethodComparator-lt
$type:
- NumericalCheckMethod
hasValue: "0.5"
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.7
identifier: 2.3.8.7
asText: ","
$type:
- Statement
- asText: "after which there shall be a horizontal intermediate landing with a length of at least 2,000 millimetres"
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.8
identifier: 2.3.8.8
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.8_method
identifier: 2.3.8.8_method
hasBSDDTarget:
$id: terms:Contains
$type:
- $id
$type:
- CompositeCheckMethod
hasNestedValue:
- $type:
- CompositeCheckMethod
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.8_method.2
hasComparator: CheckMethodComparator-logicalAND
hasNestedTarget:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.8_method.2.1
identifier: 2.3.8.8_method.2.1
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:Landing
$type:
- $id
$type:
- CategoryCheckMethod
hasNestedValue:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.8_method.2.2
identifier: 2.3.8.8_method.2.2
hasBSDDTarget:
$id: terms:LandingLength
$type:
- $id
hasComparator: CheckMethodComparator-ge
$type:
- NumericalCheckMethod
hasValue: "2"
hasOperator: CheckMethodOperator-exists
$type:
- CheckStatement
- ExceptionStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.8.9
identifier: 2.3.8.9
asText: "."
$type:
- Statement
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.9
identifier: 2.3.9
hasInlinePart:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.9.1
identifier: 2.3.9.1
asText: "However, in an"
$type:
- Statement
- asText: outdoor
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.9.2
identifier: 2.3.9.2
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.9.2_method
identifier: 2.3.9.2_method
hasBSDDTarget:
$id: terms:External
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
$type:
- CheckStatement
- ApplicationStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.9.3
identifier: 2.3.9.3
asText: area the ramp may have a
$type:
- Statement
- asText: gradient of more than five per cent
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.9.4
identifier: 2.3.9.4
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.9.4_method
identifier: 2.3.9.4_method
hasBSDDTarget:
$id: terms:Gradient
$type:
- $id
hasComparator: CheckMethodComparator-gt
$type:
- NumericalCheckMethod
hasValue: "5"
hasUnit:
$type:
- $id
$id: units:percent
$type:
- CheckStatement
- ApplicationStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.9.5
identifier: 2.3.9.5
asText: only if it can be kept in a condition comparable with that of an indoor ramp.
$type:
- Statement
- asText: "Provisions on railings, handrails and other arrangements intended to prevent falling down and misstepping are laid down by decree issued under section 117d, subsection 2 of the Land Use and Building Act"
$id: FI/Government_Decree_on_Accessibility_of_building/2.3.9.6
identifier: 2.3.9.6
references: Land Use and Building Act.117.d.2
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.3.9.7
identifier: 2.3.9.7
asText: "."
$type:
- Statement
$type:
- CheckStatement
- RequirementStatement
- $type:
- Statement
- RequirementStatement
$id: FI/Government_Decree_on_Accessibility_of_building/2.4
identifier: "2.4"
hasInlinePart:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.4.1
identifier: 2.4.1
hasInlinePart:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.1
identifier: 2.4.1.1
asText: If
$type:
- Statement
- asText: "parking spaces are provided for a building,"
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.2
identifier: 2.4.1.2
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.2_method
identifier: 2.4.1.2_method
hasBSDDTarget:
$id: terms:Contains
$type:
- $id
$type:
- CompositeCheckMethod
hasNestedValue:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.2_method.2
identifier: 2.4.1.2_method.2
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:ParkingSpace
$type:
- $id
$type:
- CategoryCheckMethod
hasOperator: CheckMethodOperator-exists
$type:
- CheckStatement
- ApplicationStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.3
identifier: 2.4.1.3
asText: an
$type:
- Statement
- asText: adequate number of them
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.4
identifier: 2.4.1.4
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.4_method
identifier: 2.4.1.4_method
hasBSDDTarget:
$id: terms:HasAppropriateNumberOfDisabledParkingSpaces
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.5
identifier: 2.4.1.5
asText: ","
$type:
- Statement
- asText: but at least one
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.6
identifier: 2.4.1.6
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.6_method
identifier: 2.4.1.6_method
hasBSDDTarget:
$id: terms:Contains
$type:
- $id
$type:
- CompositeCheckMethod
hasNestedValue:
- $type:
- CompositeCheckMethod
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.6_method.2
hasComparator: CheckMethodComparator-logicalAND
hasNestedTarget:
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.6_method.2.1
identifier: 2.4.1.6_method.2.1
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:ParkingSpace
$type:
- $id
$type:
- CategoryCheckMethod
hasNestedValue:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.6_method.2.2
identifier: 2.4.1.6_method.2.2
hasBSDDTarget:
$id: terms:IsAccessible
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
hasOperator: CheckMethodOperator-exists
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.7
identifier: 2.4.1.7
asText: ", shall be intended for the use of a person with mobility and functional impairment."
$type:
- Statement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.8
identifier: 2.4.1.8
asText: Such a
$type:
- Statement
- asText: parking space
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.9
identifier: 2.4.1.9
isOperationalizedBy:
$type:
- CompositeCheckMethod
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.9_method
hasComparator: CheckMethodComparator-logicalAND
hasNestedTarget:
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.9_method.1
identifier: 2.4.1.9_method.1
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:ParkingSpace
$type:
- $id
$type:
- CategoryCheckMethod
hasNestedValue:
- $id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.9_method.2
identifier: 2.4.1.9_method.2
hasBSDDTarget:
$id: terms:IsAccessible
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
$type:
- CheckStatement
- ApplicationStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.10
identifier: 2.4.1.10
asText: shall have a width of at least
$type:
- Statement
- asText: "3,600 millimetres"
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.11
identifier: 2.4.1.11
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.11_method
identifier: 2.4.1.11_method
hasBSDDTarget:
$id: terms:Width
$type:
- $id
hasComparator: CheckMethodComparator-ge
$type:
- NumericalCheckMethod
hasValue: "3.6"
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.12
identifier: 2.4.1.12
asText: and a length of at
$type:
- Statement
- asText: "least 5,000 millimetres"
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.13
identifier: 2.4.1.13
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.13_method
identifier: 2.4.1.13_method
hasBSDDTarget:
$id: terms:Length
$type:
- $id
hasComparator: CheckMethodComparator-le
$type:
- NumericalCheckMethod
hasValue: "5"
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.14
identifier: 2.4.1.14
asText: and be marked with the
$type:
- Statement
- asText: International Symbol of Access.
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.15
identifier: 2.4.1.15
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.1.15_method
identifier: 2.4.1.15_method
hasBSDDTarget:
$id: terms:MarkedWithInternationalSymbolOfAccess
$type:
- $id
hasComparator: CheckMethodComparator-eq
$type:
- BooleanCheckMethod
hasValue: "true"
$type:
- CheckStatement
- RequirementStatement
$type:
- CheckStatement
- RequirementStatement
- $id: FI/Government_Decree_on_Accessibility_of_building/2.4.2
identifier: 2.4.2
asText: The provisions of this subsection do not apply to a
$type:
- Statement
- asText: "detached house, semi-detached house or townhouse."
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.3
identifier: 2.4.3
isOperationalizedBy:
$id: FI/Government_Decree_on_Accessibility_of_building/2.4.3_method
identifier: 2.4.3_method
hasBSDDTarget:
$id: terms:type
$type:
- $id
hasComparator: CheckMethodComparator-eq
hasBSDDValue:
$id: terms:House
$type:
- $id
$type:
- CategoryCheckMethod
$type:
- CheckStatement
- ExceptionStatement